Sign In | Join Free | My hardware-wholesale.com
China Beijing Tianyihongda Science & Technology Development Co., LTD logo
Beijing Tianyihongda Science & Technology Development Co., LTD
Sincerity Is Fundamental, Clients Is The First. Strict Quality Control, Earnest Service Supply.
Site Member

7 Years

Home > Fault Path Indicator >

Short Circuit Earth Fault Path Indicator Detection System Device For Overhead Line

Beijing Tianyihongda Science & Technology Development Co., LTD
Contact Now

Short Circuit Earth Fault Path Indicator Detection System Device For Overhead Line

Brand Name : Tianyihongda

Model Number : TYHD-AI6

Place of Origin : China, Beijing

MOQ : 1

Price : Negotiation

Payment Terms : L/C, T/T, Western Union

Supply Ability : 3000sets per month

Delivery Time : 3-5 working days

Packaging Details : export standard

function : fault location and detection

material : plastic and exposy resin

transmission mode : wireless

protocal : IEC101, 104

Contact Now

Features for communicable indicators
Fault judge: identifying the Short-circuit fault , without testing the action value
reset way: Timing reset, manual reset , Intelligent automatic reset (A few minutes after Tripping, once the fault is cleared, reset itself upon the power return)
Handling charge: installing and removing while line is in charging condition
Rust and corrosion protection: Structure part is made of corrosion-resistant material
Surge suppression: to eliminate the wrong phenomenon of closing inrush current
The feature of the inverse: operating characteristics of maximum protection with the substation,to improve the action accuracy
Indication: Flashing and triggering a flip
Drop: Products from a height of 1 meter free fall to the concrete floor, no damage

The technical specifications:

Environment temperature: -35℃~70℃

Humidity: 5~95%RH

Altitude: <2000m

Voltage grade: 7~110kV

Frequency: 50 Hz

Power source: taking power through the line and Built-in lithium battery of 3.6V, more than 10 years

shelf lifeIndication: three high-intensity red LEDs, 360-degree visibility

Main features for Remote transmission units

1. GSM or GPRS forwarding

GSM (short messages) and GPRS (data) are mutually the standby mode, which are used to send the substation condition, circuit load current, indicator status and fault information to main distribution network station, to ensure the reliable transmitting of distribution network fault information.

2. Remote upgrade

The equipment program can be upgraded conveniently through master remote maintenance station.

3. Work mode setting

The terminal can be in the two-remote or one-remote working mode by setting the intrinsic parameters of remote terminal uint.

Two-remote working mode: the terminal is online in real time, and the circuit load current and circuit status can be uploaded.

One-remote working mode: the terminal is online regularly; when the circuit breaks down, the terminal opens GPRS module power supply and sends the fault information to main distribution network station.

4. Functions

4.1. Wireless receiving: the fault point information and load current information sent by indicator are received via short-range wireless network mode.

4.2. GSM or GPRS forwarding: GSM (short messages) and GPRS (data) are mutually the standby mode, which are used to send the substation condition, circuit load current, indicator status and fault information to main distribution network station, to ensure the reliable transmitting of distribution network fault information.

4.3. Solar power supply: the solar power supply mode is applied, and the maintenance-free 8AH lead-acid battery or 12AH lithium iron phosphate battery is provided, with the working temperature range of both batteries of -35℃~75 ℃ and -20℃~75℃ separately.

4.4 Optional communication protocol: IEC870-5-101 protocol or 104 can be selected for the connection with the third party equipment to upload the fault and shift information.

4.5. Remote upgrade: the equipment program can be upgraded conveniently through master remote maintenance station.

4.6. Convenient maintenance: the parameter setting and equipment maintenance can be performed conveniently via wireless setting terminal.

4.7. Event recording: the device can record the maximum 500 pieces of SOE events, providing the rich data support for system fault analysis.

Short Circuit Earth Fault Path Indicator Detection System Device For Overhead Line Short Circuit Earth Fault Path Indicator Detection System Device For Overhead Line

Short Circuit Earth Fault Path Indicator Detection System Device For Overhead Line


Product Tags:

power supply failure indicator

      

electrical line locator

      
China Short Circuit Earth Fault Path Indicator Detection System Device For Overhead Line wholesale

Short Circuit Earth Fault Path Indicator Detection System Device For Overhead Line Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing Tianyihongda Science & Technology Development Co., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)